Trio-motion-technology MC403 Manuale Utente Pagina 4

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 8
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 3
Aout
0V
100R
100nF
0V
D to A
CONVERTER
Ain
0V
22k
22k
30pF
A to D
CONVERTER
0V
I/O 24V must be applied to power the voltage outputs. (MC403 ONLY)
or N/C = MC403-Z
or N/C = MC403-Z
MC 403
I/O CONNECTOR 2
WDOG / Analogue Inputs / Outputs
Analogue Out Axis 1
Analogue 0V
Analogue Out Axis 0
Analogue Input 1
Analogue Input 0
Analogue 0V
WDOG
WDOG
ANALOGUE INPUT S
AIN0: 0 TO 10V
AIN1: 0 TO 10V
ANALOGUE OUTPUTS
AOUT 0 TO AOUT 1
Output: +/-10V at 5mA
Output impedance: 100 Ohms.
Common 0V return. Isolated from I/O & Encoders.
MC403 ONLY